DTE safety edges are mechanical activation enclosed in a soft rubber extrusion. Mechanical edges are more rugged than resistive edges, but have a higher switch point. They are suitable for fast moving edges such as the end of a sliding gate.
The edge responds to front pressure and side force. These taught wire edges have three mechanical micro-switches, two for activation and one for wire failure. The wire must be kept at the correct tension.
DTE connects on two terminals. Place the jumper link near the terminals for "normally closed" output, or away from the terminals for "8k2" output.
The DTE should be mounted withe the terminal end at the top to prevent water ingress.